User Tools

This is an old revision of the document!


BMS EX

Version 206

- define GLOB_CLUSTER_COMS_REVISION Version 4

- Feat: Detecting irregular difference in clusterCurrent to indicate burnt fuse ** this feature is avaialble if only all nodes are min ClusterVer: 4. This is a beta feat not enabled by default

- add BC[01][6] abs shunt current in Ax10

- Min top capacity alignment with parameter default=90, if cluster cap = 100 (one node has 100% soc) and if bat is lower than 90 will jump to 90% SoC

- Added remote device Disabled/None

- Fixed LED settings from Logger, min Logger fw:9.150

- Fixed not showing Warning in AutoCan remote device

- Fixed BUG showing Warning at PButton for WARNING_CODE_MASTER_MSG_MISSING, since 204

Version 205

- Cluster capacity SoC using liner ratio between avrg and limits, John Basson

Version 204

- HV mode first release - PButton does not show warnings WARNING_CODE_MASTER_MSG_MISSING - If turned ON from PButton and no Remote signal available BMS starts always in LV - BMU fw:200+ changes mode to HV automatically

Version 202

- add production flag for replacement BmsEx marking

- remove relay operation mode, always in auto since manual mode causes potential danger

Version 201

- add system uptime read from logger

- add extra information for startup event, showing last shutdown environment, information is available only when read from logger ver 9.110 or higher

- add remote restart and shutdown instruction for developers

- add MAX14921 capacitor leak detection and error compensation

- add cell capacity for individual cells

- add cell balancing mode Capacity and Auto, Auto is mixed of fine voltage based balancing combined with rough capacity based balancing. Mode auto will be set as default

- Cluster data change, causing cluster FW change to 2

- Split temperature current limit to separate value.

- add broadcast fw update allowing logger to update multiple at same time

- reseting cell compensation per module battery

- add raw pack voltage as BC information

- changed all remote device to Broadcast raw voltage only

- Cluster parameters are automatically distributed to all slaves, and changing parameters is prohibited in slave mode

- Remote device auto scan for most of the device in 500k range

- PushButton menu 3 added for reset CtrlDev to Auto

- and much more

Version 194

- add Solis supported device

- add Cluster overwrite test instruction for testing remote control device response

- add capacity correction at startup based on average voltage and minimum time between startups

Version 193

- chCtrlIncreaseDelay change default from 180 to 15 complains from support. forcing parameter on firmware change to write param to 15

Version 192

- Deye send Raw voltage fix

- Broadcast of raw pack voltage

Version 191

- Fixed cluster firmware version not to give warning when no cluster changes made

- Victron default speed change to parameter with default 500k

Version 190

Version 189

- Fixed calibration test env Speed causing conflict with can1

- Fixed Nikolay Bashev issue button turn off at shutdown

Version 188

- Cluster coms version changes to separate number.

Version 187

- Fixed canbus2 baudrate BUG.

Version 186

- Fixed canbus2 baudrate selection change.

- Fixed canbus2 baudrate fixed speed for specific devices.

Version 185

- Rem Ctrl Dev Sunsynk settings for disable coms monitor.

Version 184

- High Voltage standalone mode, Balancing in cluster

- Added Remote device LV generic charger

- Rem Dev Sunsynk send voltage without compensation mode

- Cluster value Size changed to accomodate voltage greater than 0xFFFF

Version 183

- Memory mutex causing deadlock removed

Version 182

- Replace WDT call with non blocking call

Version 181

- Production Erase EEPROM PAGE PARAM added to CANBUS instruction set

Version 180

- Production functionality extended, Production errors added

- Sunsynk direct coms parameter to disable CANBUS monitoring for inverter warning.

- RTC SD3077 support added for HW: 303

- Preserving capacity small bug fix;

- Absolute average current measurement with buffer added

- Response after Reboot and Shutdown instruction over CANBUS.

Version 179

- Removing Offset from cell measuring. use only AFE SDADC offset

Version 178

- CANBUS remote clearing interface register CCCR for error recover.

- Sending probe msg when master missing for CAN-Remote line status detection.

Version 177

- Interface stat

Version 176

- Growatt control device Snapshot 1

Version 175

- Charge Ctrl voltage Counter not working fix

Version 174

- Second Average buffer added with size of 16 in addition to 5sec main.

- Remaining time replacing Average current in CAN BC.

Version 173

- Energy Counter bug fixed accumulation from TC.

Version 172

- Led Menu first Item load Bug fix.

- Remote Device Sunsynk no message warning delay increased to 7500ms.

- BMS does not generate Warning for missing cluster node if remote device is set to None.

Version 171

- Sma Remote device.

- Led Menu add option 3 for Remote Device.

- Led Menu removed option 2 for Cell Count.

- Led Menu Fixed start with parameter 1.

Version 170

- Cluster functionality.

Version 167

- Override clear warning on complete.

Version 166

- Balancing circuit measurement

Version 165

- Ina param read from CANBUS [INSTR_DATA_INA_PARAM 11]

- Balancing current limit FIXED

- LED Param read write over CANBUS

You could leave a comment if you were logged in.

This website uses cookies. By using the website, you agree with storing cookies on your computer. Also, you acknowledge that you have read and understand our Privacy Policy. If you do not agree, please leave the website.

More information