Version 203
- Date: 20/03/2025
- List Of Changes:
- HV mode SNAPOSHOT: force GLOB_OPMODE_NORMAL_HV_STANDALONE to GLOB_OPMODE_STANDALONE
- Reason for change: NA
- Cluster date percent values uses smallest or highest not average
- Reason for change: improvement, SMD-ISSUE#585
Version 202
- Date: 04/02/2025
- List Of Changes:
- Add production flag for replacement BmsEx marking
- Reason for change: NA
- Remove relay operation mode, always in auto since manual mode causes potential danger
- Reason for change: NA
Version 201
- Date: NA
- List Of Changes:
- Add system uptime read from logger
- Reason for change: NA
- Add extra information for startup event, showing last shutdown environment, information is available only when read from logger ver 9.110 or higher
- Reason for change: NA
- Add remote restart and shutdown instruction for developers
- Reason for change: NA
- Add MAX14921 capacitor leak detection and error compensation
- Reason for change: NA
- Add cell capacity for individual cells
- Reason for change: NA
- Add cell balancing mode Capacity and Auto, Auto is mixed of fine voltage based balancing combined with rough capacity based balancing.Mode auto will be set as default
- Reason for change: NA
- Cluster data change, causing cluster FW change to 2
- Reason for change: NA
- Split temperature current limit to separate value
- Reason for change: NA
- Add broadcast fw update allowing logger to update multiple at same time
- Reason for change: NA
- Resetting cell compensation per module battery
- Reason for change: NA
- Add raw pack voltage as BC information
- Reason for change: NA
- Changed all remote device to Broadcast raw voltage only
- Reason for change: NA
- Cluster parameters are automatically distributed to all slaves, and changing parameters is prohibited in slave mode
- Reason for change: NA
- Remote device auto scan for most of the device in 500k range
- Reason for change: NA
- PushButton menu 3 added for reset CtrlDev to Auto
- Reason for change: NA
Version 194
- Date: NA
- List Of Changes:
- Add Solis supported device
- Reason for change: NA
- Add Cluster overwrite test instruction for testing remote control device response
- Reason for change: NA
- Add capacity correction at startup based on average voltage and minimum time between startups
- Reason for change: NA
Version 193
- Date: NA
- List Of Changes:
- chCtrlIncreaseDelay change default from 180 to 15 complaints from support forcing parameter on firmaware change to write param to 15
- Reason for change: NA
Version 192
- Date: NA
- List Of Changes:
- Deye send Raw voltage fix
- Reason for change: NA
- Broadcast of raw pack voltage
- Reason for change: NA
Version 191
- Date: NA
- List Of Changes:
- Fixed cluster firmware version not to give warning when no cluster changes made
- Reason for change: NA
- Victron default speed change to parameter with default 500k
- Reason for change: NA
Version 189
- Date: NA
- List Of Changes:
- Fixed calibration test env Speed causing conflict with can1
- Reason for change: NA
- Fixed Nikolay Bashev issue button turn off at shutdown
- Reason for change: NA
Version 188
- Date: NA
- List Of Changes:
- Cluster coms version changes to separate number
- Reason for change: NA
Version 187
- Date: NA
- List Of Changes:
- Fixed canbus2 baudrate BUG
- Reason for change: NA
Version 186
- Date: NA
- List Of Changes:
- Fixed canbus2 baudrate selection change
- Reason for change: NA
- Fixed canbus2 baudrate fixed speed for specific devices
- Reason for change: NA
Version 185
- Date: 06/11/2022
- List Of Changes:
- Rem Ctrl Dev Sunsynk settings for disable coms monitor
- Reason for change: NA
Version 184
- Date: NA
- List Of Changes:
- High Voltage standalone mode, Balancing in cluster
- Reason for change: NA
- Added Remote device LV generic charger
- Reason for change: NA
- Rem Dev Sunsynk send voltage without compensation mode
- Reason for change: NA
- Cluster value Size changed to accomodate voltage greater than 0xFFFF
- Reason for change: NA
Version 183
- Date: NA
- List Of Changes:
- Memory mutex causing deadlock removed
- Reason for change: NA
Version 182
- Date: NA
- List Of Changes:
- Replace WDT call with non blocking call
- Reason for change: NA
Version 181
- Date: 19/06/2022
- List Of Changes:
- Production Erase EEPROM PAGE PARAM added to CANBUS instruction set
- Reason for change: NA
Version 180
- Date: NA
- List Of Changes:
- Production functionality extended, Production errors added
- Reason for change: NA
- Sunsynk direct coms parameter to disable CANBUS monitoring for inverter warning
- Reason for change: NA
- RTC SD3077 support added for HW: 303
- Reason for change: NA
- Preserving capacity small bug fix
- Reason for change: NA
- Absolute average current measurement with buffer added
- Reason for change: NA
- Response after Reboot and Shutdown instruction over CANBUS
- Reason for change: NA
Version 179
- Date: NA
- List Of Changes:
- Removing Offset from cell measuring. use only AFE SDADC offset
- Reason for change: NA
Version 178
- Date: NA
- List Of Changes:
- CANBUS remote clearing interface register CCCR for error recover
- Reason for change: NA
- Sending probe msg when master missing for CAN-Remote line status detection
- Reason for change: NA
Version 177
- Date: 05/03/2022
- List Of Changes:
- Interface stat
- Reason for change: NA
Version 176
- Date: NA
- List Of Changes:
- Growatt control device Snapshot 1
- Reason for change: NA
Version 175
- Date: NA
- List Of Changes:
- Charge Ctrl voltage Counter not working fix
- Reason for change: NA
Version 174
- Date: NA
- List Of Changes:
- Second Average buffer added with size of 16 in addition to 5sec main
- Reason for change: NA
- Remaining time replacing Average current in CAN BC
- Reason for change: NA
Version 173
- Date: NA
- List Of Changes:
- Energy Counter bug fixed accumulation from TC
- Reason for change: NA
Version 172
- Date: NA
- List Of Changes:
- Led Menu first Item load Bug fix
- Reason for change: NA
- Remote Device Sunsynk no message warning delay increased to 7500ms
- Reason for change: NA
- BMS does not generate Warning for missing cluster node if remote device is set to None
- Reason for change: NA
Version 171
- Date: NA
- List Of Changes:
- Sma Remote device
- Reason for change: NA
- Led Menu add option 3 for Remote Device
- Reason for change: NA
- Led Menu removed option 2 for Cell Count
- Reason for change: NA
- Led Menu Fixed start with parameter 1
- Reason for change: NA
Version 170
- Date: NA
- List Of Changes:
- Cluster functionality
- Reason for change: NA
Version 167
- Date: NA
- List Of Changes:
- Override clear warning on complete
- Reason for change: NA
Version 166
- Date: NA
- List Of Changes:
- Balancing circuit measurement
- Reason for change: NA
Version 165
- Date: NA
- List Of Changes:
- Ina param read from CANBUS [INSTR_DATA_INA_PARAM 11]
- Reason for change: NA
- Balancing current limit FIXED
- Reason for change: NA
- LED Param read write over CANBUS
- Reason for change: NA
Version 133
- Date: 04/10/2020
- List Of Changes:
- The Error LED has been removed during BMS startup. BMS error 0 is hidden
- Reason for change: NA
- Permanent broadcasting fixed
- Reason for change: NA
- Fixing of SMD CAN protocol
- Reason for change: NA
- Green LED blinking enhanced
- Reason for change: NA
- CANUS start using hardware ID filtering
- Reason for change: NA
Version 130
- Date: NA
- List Of Changes:
- BMS will remain updatable if an error occurs in the microcontroller, Always do update 130 before proceeding with updates >130
- Reason for change: NA
Version 124
- Date: NA
- List Of Changes:
- Charge Discharge error control fully tested
- Reason for change: NA
Version 123
- Date: NA
- List Of Changes:
- Charge Discharge Control with new 3 separate levels for Voltage Capacity and Temp, Logger update required
- Reason for change: NA
Version 122
- Date: NA
- List Of Changes:
- RGB Button fully supported with additional color for menu selection
- Reason for change: NA
You could leave a comment if you were logged in.