- define GLOB_CLUSTER_COMS_REVISION Version 4
- Feat: Detecting irregular difference in clusterCurrent to indicate burnt fuse ** this feature is avaialble if only all nodes are min ClusterVer: 4. This is a beta feat not enabled by default
- add BC[01][6] abs shunt current in Ax10
- Min top capacity alignment with parameter default=90, if cluster cap = 100 (one node has 100% soc) and if bat is lower than 90 will jump to 90% SoC
- Added remote device Disabled/None
- Fixed LED settings from Logger, min Logger fw:9.150
- Fixed not showing Warning in AutoCan remote device
- Fixed BUG showing Warning at PButton for WARNING_CODE_MASTER_MSG_MISSING, since 204
- Cluster capacity SoC using liner ratio between avrg and limits, John Basson
- HV mode first release - PButton does not show warnings WARNING_CODE_MASTER_MSG_MISSING - If turned ON from PButton and no Remote signal available BMS starts always in LV - BMU fw:200+ changes mode to HV automatically
- add production flag for replacement BmsEx marking
- remove relay operation mode, always in auto since manual mode causes potential danger
- add system uptime read from logger
- add extra information for startup event, showing last shutdown environment, information is available only when read from logger ver 9.110 or higher
- add remote restart and shutdown instruction for developers
- add MAX14921 capacitor leak detection and error compensation
- add cell capacity for individual cells
- add cell balancing mode Capacity and Auto, Auto is mixed of fine voltage based balancing combined with rough capacity based balancing. Mode auto will be set as default
- Cluster data change, causing cluster FW change to 2
- Split temperature current limit to separate value.
- add broadcast fw update allowing logger to update multiple at same time
- reseting cell compensation per module battery
- add raw pack voltage as BC information
- changed all remote device to Broadcast raw voltage only
- Cluster parameters are automatically distributed to all slaves, and changing parameters is prohibited in slave mode
- Remote device auto scan for most of the device in 500k range
- PushButton menu 3 added for reset CtrlDev to Auto
- and much more
- add Solis supported device
- add Cluster overwrite test instruction for testing remote control device response
- add capacity correction at startup based on average voltage and minimum time between startups
- chCtrlIncreaseDelay change default from 180 to 15 complains from support. forcing parameter on firmware change to write param to 15
- Deye send Raw voltage fix
- Broadcast of raw pack voltage
- Fixed cluster firmware version not to give warning when no cluster changes made
- Victron default speed change to parameter with default 500k
- Fixed calibration test env Speed causing conflict with can1
- Fixed Nikolay Bashev issue button turn off at shutdown
- Cluster coms version changes to separate number.
- Fixed canbus2 baudrate BUG.
- Fixed canbus2 baudrate selection change.
- Fixed canbus2 baudrate fixed speed for specific devices.
- Rem Ctrl Dev Sunsynk settings for disable coms monitor.
- High Voltage standalone mode, Balancing in cluster
- Added Remote device LV generic charger
- Rem Dev Sunsynk send voltage without compensation mode
- Cluster value Size changed to accomodate voltage greater than 0xFFFF
- Memory mutex causing deadlock removed
- Replace WDT call with non blocking call
- Production Erase EEPROM PAGE PARAM added to CANBUS instruction set
- Production functionality extended, Production errors added
- Sunsynk direct coms parameter to disable CANBUS monitoring for inverter warning.
- RTC SD3077 support added for HW: 303
- Preserving capacity small bug fix;
- Absolute average current measurement with buffer added
- Response after Reboot and Shutdown instruction over CANBUS.
- Removing Offset from cell measuring. use only AFE SDADC offset
- CANBUS remote clearing interface register CCCR for error recover.
- Sending probe msg when master missing for CAN-Remote line status detection.
- Interface stat
- Growatt control device Snapshot 1
- Charge Ctrl voltage Counter not working fix
- Second Average buffer added with size of 16 in addition to 5sec main.
- Remaining time replacing Average current in CAN BC.
- Energy Counter bug fixed accumulation from TC.
- Led Menu first Item load Bug fix.
- Remote Device Sunsynk no message warning delay increased to 7500ms.
- BMS does not generate Warning for missing cluster node if remote device is set to None.
- Sma Remote device.
- Led Menu add option 3 for Remote Device.
- Led Menu removed option 2 for Cell Count.
- Led Menu Fixed start with parameter 1.
- Cluster functionality.
- Override clear warning on complete.
- Balancing circuit measurement
- Ina param read from CANBUS [INSTR_DATA_INA_PARAM 11]
- Balancing current limit FIXED
- LED Param read write over CANBUS