====== BMS EX ====== ===== Version 206 ===== - define GLOB_CLUSTER_COMS_REVISION Version 4 - Feat: Detecting irregular difference in clusterCurrent to indicate burnt fuse ** this feature is avaialble if only all nodes are min ClusterVer: 4. This is a beta feat not enabled by default - add BC[01][6] abs shunt current in Ax10 - Min top capacity alignment with parameter default=90, if cluster cap = 100 (one node has 100% soc) and if bat is lower than 90 will jump to 90% SoC - Added remote device Disabled/None - Fixed LED settings from Logger, min Logger fw:9.150 - Fixed not showing Warning in AutoCan remote device - Fixed BUG showing Warning at PButton for WARNING_CODE_MASTER_MSG_MISSING, since 204 ===== Version 205 ===== - Cluster capacity SoC using liner ratio between avrg and limits, John Basson ===== Version 204 ===== - HV mode first release - PButton does not show warnings WARNING_CODE_MASTER_MSG_MISSING - If turned ON from PButton and no Remote signal available BMS starts always in LV - BMU fw:200+ changes mode to HV automatically ===== Version 202 ===== - add production flag for replacement BmsEx marking - remove relay operation mode, always in auto since manual mode causes potential danger ===== Version 201 ===== - add system uptime read from logger - add extra information for startup event, showing last shutdown environment, information is available only when read from logger ver 9.110 or higher - add remote restart and shutdown instruction for developers - add MAX14921 capacitor leak detection and error compensation - add cell capacity for individual cells - add cell balancing mode Capacity and Auto, Auto is mixed of fine voltage based balancing combined with rough capacity based balancing. Mode auto will be set as default - Cluster data change, causing cluster FW change to 2 - Split temperature current limit to separate value. - add broadcast fw update allowing logger to update multiple at same time - reseting cell compensation per module battery - add raw pack voltage as BC information - changed all remote device to Broadcast raw voltage only - Cluster parameters are automatically distributed to all slaves, and changing parameters is prohibited in slave mode - Remote device auto scan for most of the device in 500k range - PushButton menu 3 added for reset CtrlDev to Auto - and much more ===== Version 194 ===== - add Solis supported device - add Cluster overwrite test instruction for testing remote control device response - add capacity correction at startup based on average voltage and minimum time between startups ===== Version 193 ===== - chCtrlIncreaseDelay change default from 180 to 15 complains from support. forcing parameter on firmware change to write param to 15 ===== Version 192 ===== - Deye send Raw voltage fix - Broadcast of raw pack voltage ===== Version 191 ===== - Fixed cluster firmware version not to give warning when no cluster changes made - Victron default speed change to parameter with default 500k ===== Version 190 ===== ===== Version 189 ===== - Fixed calibration test env Speed causing conflict with can1 - Fixed Nikolay Bashev issue button turn off at shutdown ===== Version 188 ===== - Cluster coms version changes to separate number. ===== Version 187 ===== - Fixed canbus2 baudrate BUG. ===== Version 186 ===== - Fixed canbus2 baudrate selection change. - Fixed canbus2 baudrate fixed speed for specific devices. ===== Version 185 ===== - Rem Ctrl Dev Sunsynk settings for disable coms monitor. ===== Version 184 ===== - High Voltage standalone mode, Balancing in cluster - Added Remote device LV generic charger - Rem Dev Sunsynk send voltage without compensation mode - Cluster value Size changed to accomodate voltage greater than 0xFFFF ===== Version 183 ===== - Memory mutex causing deadlock removed ===== Version 182 ===== - Replace WDT call with non blocking call ===== Version 181 ===== - Production Erase EEPROM PAGE PARAM added to CANBUS instruction set ===== Version 180 ===== - Production functionality extended, Production errors added - Sunsynk direct coms parameter to disable CANBUS monitoring for inverter warning. - RTC SD3077 support added for HW: 303 - Preserving capacity small bug fix; - Absolute average current measurement with buffer added - Response after Reboot and Shutdown instruction over CANBUS. ===== Version 179 ===== - Removing Offset from cell measuring. use only AFE SDADC offset ===== Version 178 ===== - CANBUS remote clearing interface register CCCR for error recover. - Sending probe msg when master missing for CAN-Remote line status detection. ===== Version 177 ===== - Interface stat ===== Version 176 ===== - Growatt control device Snapshot 1 ===== Version 175 ===== - Charge Ctrl voltage Counter not working fix ===== Version 174 ===== - Second Average buffer added with size of 16 in addition to 5sec main. - Remaining time replacing Average current in CAN BC. ===== Version 173 ===== - Energy Counter bug fixed accumulation from TC. ===== Version 172 ===== - Led Menu first Item load Bug fix. - Remote Device Sunsynk no message warning delay increased to 7500ms. - BMS does not generate Warning for missing cluster node if remote device is set to None. ===== Version 171 ===== - Sma Remote device. - Led Menu add option 3 for Remote Device. - Led Menu removed option 2 for Cell Count. - Led Menu Fixed start with parameter 1. ===== Version 170 ===== - Cluster functionality. ===== Version 167 ===== - Override clear warning on complete. ===== Version 166 ===== - Balancing circuit measurement ===== Version 165 ===== - Ina param read from CANBUS [INSTR_DATA_INA_PARAM 11] - Balancing current limit FIXED - LED Param read write over CANBUS